ASTM F1871-24 PDF

St ASTM F1871-24

Name in English:
St ASTM F1871-24

Name in Russian:
Ст ASTM F1871-24

Description in English:

Original standard ASTM F1871-24 in PDF full version. Additional info + preview on request

Description in Russian:
Оригинальный стандарт ASTM F1871-24 в PDF полная версия. Дополнительная инфо + превью по запросу
Document status:
Active

Format:
Electronic (PDF)

Delivery time (for English version):
1 business day

Delivery time (for Russian version):
200 business days

SKU:
stastm15832

Choose Document Language:
€15

Full title and description

Standard Specification for Folded/Formed Poly-(Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation — a short specification that establishes material, dimensional and performance requirements for factory‑made folded/formed PVC (polyvinyl chloride) Type A liners intended for trenchless rehabilitation of existing sewers and conduits.

Abstract

This specification covers requirements and related test methods for materials, dimensions, workmanship, chemical resistance, joint tightness and other performance characteristics of folded/formed PVC pipe (Type A) used as structural or semi‑structural liners for rehabilitation of existing gravity sewer and conduit systems. It also addresses four‑inch perforated pipe (with limited applicability of joint‑tightness tests) and includes provisions for marking and conformance testing.

General information

  • Status: Active / Current.
  • Publication date: February 1, 2024.
  • Publisher: ASTM International.
  • ICS / categories: 23.040.20 (Plastic pipes); 83.080.20 (Thermoplastic materials).
  • Edition / version: F1871-24 (2024 edition).
  • Number of pages: 7 pages.

Scope

The standard applies to folded/formed factory‑made PVC Type A liner pipe used for rehabilitation of existing sewer and conduit systems by trenchless methods. It specifies the required PVC compound (including allowance for recycled material where permitted), dimensional tolerances, workmanship, mechanical and chemical performance tests (for example flattening resistance, impact resistance and stiffness), joint tightness criteria (where applicable), and marking to demonstrate conformity. The specification clarifies special treatment of small perforated product (four‑inch) where joint tests are not applied.

Key topics and requirements

  • Material specification for PVC compound (virgin or permitted recycled content).
  • Dimensional tolerances and marking requirements for traceability.
  • Workmanship and visual/defect acceptance criteria.
  • Chemical resistance requirements relevant to sewer environments.
  • Mechanical performance tests including flattening resistance, impact strength and stiffness.
  • Joint tightness testing procedures and acceptance (except where explicitly not applicable, e.g., certain perforated products).
  • Requirements for solvent cement or jointing methods where relevant and for perforated product characteristics.

Typical use and users

Used by municipal utilities, consulting engineers, trenchless rehabilitation contractors, liner manufacturers, specifiers and owners who need a prescriptive specification for folded/formed PVC Type A liners for gravity sewer and conduit rehabilitation (including projects that require factory‑fabricated structural or semi‑structural liners). Also used by quality/control laboratories and procurement teams preparing technical specifications and purchase orders.

Related standards

Commonly referenced complementary standards and practices in trenchless and PVC sewer pipe work include ASTM practices for cured‑in‑place liners (for example ASTM F1216), other PVC sewer pipe specifications (such as ASTM D3034), and ASTM standards for gasket/seal materials and joint testing. These documents are frequently used together when preparing rehabilitation project specifications and test programs.

Keywords

PVC, polyvinyl chloride, folded/form‑formed pipe, Type A, sewer rehabilitation, conduit rehabilitation, trenchless, liner, joint tightness, flattening resistance, impact strength, stiffness, solvent cement, marking.

FAQ

Q: What is this standard?

A: ASTM F1871-24 is a 2024 ASTM International specification that sets material, dimensional and performance requirements for folded/form‑formed PVC Type A pipe intended for use as factory‑made liners in the repair and rehabilitation of existing sewer and conduit systems.

Q: What does it cover?

A: It covers PVC compound requirements, workmanship, dimensional tolerances, chemical resistance, tests for flattening resistance, impact and stiffness, joint tightness (where applicable), and marking/identification for conformity. It also notes special handling for certain small perforated products.

Q: Who typically uses it?

A: Municipal and utility owners, consulting and design engineers, trenchless rehabilitation contractors, liner manufacturers, testing labs, and procurement/specification writers involved in sewer and conduit rehabilitation projects.

Q: Is it current or superseded?

A: The F1871-24 edition is the active (current) ASTM edition published on February 1, 2024; users should check with ASTM or their standards subscription for any amendments or revisions after that date.

Q: Is it part of a series?

A: It sits within the body of ASTM standards for plastic pipes and trenchless rehabilitation (the F17 committee and related subcommittees). It is commonly used alongside other ASTM pipe and rehabilitation standards such as ASTM F1216 and ASTM D3034.

Q: What are the key keywords?

A: PVC, folded/form‑formed pipe, Type A, liner, trenchless rehabilitation, sewer, conduit, joint tightness, impact resistance, stiffness.