SP 3.13130.2009 PDF

SP 3.13130.2009

Name in English:
SP 3.13130.2009

Name in Russian:
СП 3.13130.2009

Description in English:

Systems of fire protection. System of annunciation and managementof human evacuation at fire. Requirements of fire safety

Description in Russian:
Системы противопожарной защиты. Система оповещения и управления эвакуацией людей при пожарах. Требования к пожарной безопасности
Document status:
Active

Format:
Electronic (PDF)

Page count:
10

Delivery time (for English version):
1 business day

Delivery time (for Russian version):
1 business day

SKU:
SP 3.13130.2009

Choose Document Language:
€24

Full title and description

SP 3.13130.2009 — Systems of fire protection. System of annunciation and management of human evacuation at fire. Requirements of fire safety. (Russian: СП 3.13130.2009 — Системы противопожарной защиты. Система оповещения и управления эвакуацией людей при пожарах. Требования к пожарной безопасности.) This set of rules establishes safety requirements and basic design, installation and operation principles for warning and evacuation‑management systems (voice, sound and light) in buildings and structures.

Abstract

SP 3.13130.2009 is a regulatory "Svod pravil" that defines minimum fire‑safety requirements for systems of annunciation and for managing the evacuation of people during fires. It covers classification of evacuation systems, technical requirements for voice/sound and light signalling, zoning and selection criteria for system types, interfaces with fire‑alarm and fire‑suppression equipment, and provisions for maintenance, testing and accessibility (including provisions for people with limited mobility).

General information

  • Status: Active / in force (introduced and applied as a Svod pravil for voluntary standardization).
  • Publication date: Approved by order of the Russian Ministry of Emergency Situations (MChS) on 25 March 2009; entry into force (effective) 1 May 2009.
  • Publisher: Developed by FGU VNIIPO (the Fire Safety Research Institute of the Russian MChS); published/registered as a national set of rules.
  • ICS / categories: Classified under fire‑safety / annunciation systems (OKS/ICS reference commonly shown as 13.220.20 — fire detection and alarm systems related group).
  • Edition / version: Original edition 2009 (СП 3.13130.2009). Note: later normative acts and consolidated rules affecting related topics have been published; users should check national registries for the latest consolidated rules when designing major projects.
  • Number of pages: ~11 pages (typical published PDF/leaflet size — edition sizes reported by standard distributors vary slightly).

Scope

The document applies to the design, construction, reconstruction, technical re‑equipping, installation, operation and maintenance of systems for annunciation and management of human evacuation in buildings and structures. It establishes minimum fire‑safety requirements for voice/sound and light signalling, classification of system types (SOUÉ / СОУЭ), criteria for selecting the appropriate system type for a given building function and occupancy, and rules for interaction with automatic fire‑alarm and fire‑suppression systems. The Svod pravil may be used when developing special technical conditions for projects.

Key topics and requirements

  • Classification of evacuation‑announcement systems (types of СОУЭ) and criteria for choosing a system type based on building function, occupancy and area.
  • Technical requirements for sound and voice evacuation signalling (speech intelligibility, sound levels, zonal partitioning, permitted use of sirens vs. voice in specific areas).
  • Requirements for light (visual) signalling and combined audio‑visual evacuation aids.
  • Interfaces and mandatory interactions with automatic fire‑alarm systems (AУПС), smoke control and automatic fire‑suppression equipment; command and signalling logic for evacuation management.
  • Provisions for emergency two‑way communication and assistance for people with limited mobility (MГН) including special signalling and dispatcher interfaces.
  • Installation, commissioning, periodic testing, maintenance, and documentation requirements to ensure systems remain operational and compliant.
  • Rules for zoning, speaker placement, power supply redundancy and survivability of critical components during fire conditions.

Typical use and users

Used by designers, fire‑safety engineers, electrical/automation contractors, building owners, system integrators and inspectors involved in the specification, design, installation, commissioning and maintenance of building evacuation annunciation systems. Applicable for public buildings, educational institutions, healthcare facilities, offices, shopping centers, transport hubs, industrial premises and other structures where organized evacuation procedures are required.

Related standards

SP 3.13130.2009 is part of a family of Russian "SP" documents on fire protection systems. Closely related and commonly referenced documents include SP 5.13130.2009 (design norms for automated fire‑alarm and firefighting installations; later consolidated/updated documents on fire‑alarm and automation exist), SP 4.13130.x series (requirements to limit fire spread and layout), and other topical SPs and national technical regulations (e.g., Federal Law and Technical Regulations on fire safety). Users commonly consult these neighboring documents when designing integrated fire‑protection systems.

Keywords

SP 3.13130.2009; СОУЭ; SOUE; evacuation system; voice evacuation; fire annunciation; fire safety requirements; sound signalling; light signalling; MChS; VNIIPO; fire alarm interface; evacuation management.

FAQ

Q: What is this standard?

A: SP 3.13130.2009 is a Russian set of rules (Svod pravil) specifying fire‑safety requirements for systems that announce and manage the evacuation of people during a fire (voice, sound and light systems).

Q: What does it cover?

A: It covers classification of evacuation systems (types of СОУЭ), design and performance requirements for voice/sound and light signalling, zoning and selection criteria, interfaces with fire‑alarm and suppression systems, provisions for people with limited mobility, and rules for installation, testing and maintenance.

Q: Who typically uses it?

A: Fire‑safety engineers, building/system designers, contractors, integrators, facility managers and regulators involved in specifying, installing, commissioning and maintaining evacuation announcement and management systems.

Q: Is it current or superseded?

A: SP 3.13130.2009 was approved 25 March 2009 and came into force 1 May 2009; it has been applied since then and remained referenced in national registries (checks of official registries show active status in recent years). However, parts of the regulatory framework for alarm/automation have been consolidated and updated in later documents (from 2020 onward) — for major projects you should verify the current applicable rules and any newer consolidated standards or departmental orders before final design.

Q: Is it part of a series?

A: Yes — it belongs to the SP series addressing systems of fire protection (the 3.13130 / 5.13130 family) and is typically used together with other SP documents covering fire‑alarm systems, fire‑resistance, layout requirements and related technical regulations.

Q: What are the key keywords?

A: СОУЭ (SOUÉ), evacuation management, voice evacuation, fire annunciation, sound signalling, light signalling, acoustic intelligibility, fire alarm interface, VNIIPO, MChS.