BS EN 61300-3-27-1997 (1999) PDF
Name in English:
STB BS EN 61300-3-27-1997 (1999)
Name in Russian:
СТБ BS EN 61300-3-27-1997 (1999)
Original standard BS EN 61300-3-27-1997 (1999) in PDF full version. Additional info + preview on request
Full title and description
STB BS EN 61300-3-27:1997 (adopted 1999) — Fibre optic interconnecting devices and passive components — Basic test and measurement procedures — Part 3-27: Examinations and measurements — Measurement method for the hole location of a multiway connector plug. This document specifies the measurement method to determine the positions of fibre holes and guide holes on the endface of multiway connector plugs to ensure correct mechanical alignment and optical performance.
Abstract
This part of the EN/IEC 61300 series defines procedures to measure the distance between guide-hole centres and the position deviation of each fibre-hole centre on multiway connector plugs used to array fibres and align pins; the measurements are intended to verify connector geometry for mechanical and optical conformity.
General information
- Status: Current / Active (base IEC publication from 1997; national adoption recorded as STB BS EN 61300-3-27 with a 1999 adoption identifier).
- Publication date: IEC base publication 23 May 1997; BSI/BS EN edition released 15 September 1997; STB national adoption shown as 1999.
- Publisher: International Electrotechnical Commission (IEC) — published as IEC 61300-3-27:1997; adopted and published in EN/BS EN form by national bodies (BSI) and recorded in STB catalogues for national publication.
- ICS / categories: 33.180.20 — Fibre optic interconnecting devices.
- Edition / version: Edition 1.0 (first published 1997).
- Number of pages: 11–12 pages depending on publisher reprint (IEC lists 11 pages; BSI/BS EN reprints commonly show 12 pages).
Scope
This standard specifies a measurement method for determining the hole locations (fibre-hole centres and guide-hole centres) on the endface of multiway connector plugs that contain multiple fibre holes and two guide holes for alignment pins; dimensions measured include the distance between guide-hole centres and the position deviation of each fibre-hole centre needed to meet mechanical and optical performance requirements.
Key topics and requirements
- Definition of measurement targets on multiway connector plug endfaces (guide-hole centre distance L and fibre-hole position deviations Pi).
- Measurement procedures and tolerancing sufficient to verify connector mechanical alignment and optical mating performance.
- Applicability to multiway connectors with multiple fibre holes and alignment-pin guide holes.
- Conformance requirements intended for use in qualification and production checking of connector geometry.
Typical use and users
Used by connector designers, manufacturing quality engineers, metrology laboratories, test houses and technicians involved in fibre‑optic connector production and inspection to verify hole locations and ensure reliable array alignment and mating. Typical applications include multi‑fibre connector qualification, production sampling and dimensional control during assembly.
Related standards
Part of the IEC/EN 61300 series (Basic test and measurement procedures) — related parts include other examinations and measurements such as visual inspection (IEC 61300-3-35 / EN 61300-3-35), end-face geometry (IEC/EN 61300-3-47) and other dimensional/optical test methods in the 61300‑3 family. Users should consult the full IEC 61300 series for complementary tests and measurement procedures.
Keywords
multiway connector plug, hole location, fibre-hole position, guide-hole, connector endface, dimensional measurement, fibre optics, IEC 61300, BS EN, STB national adoption.
FAQ
Q: What is this standard?
A: It is IEC 61300-3-27:1997 published as BS EN 61300-3-27:1997 and recorded in STB national catalogues (adoption noted in 1999), specifying measurement methods for the hole location of multiway connector plugs.
Q: What does it cover?
A: Procedures to measure the distance between guide‑hole centres and the positional deviations of fibre‑hole centres on the endface of multiway connector plugs to verify mechanical and optical alignment requirements.
Q: Who typically uses it?
A: Connector manufacturers, test laboratories, quality/production engineers and standards/requirements authors working on multi‑fibre connector design, inspection and acceptance testing.
Q: Is it current or superseded?
A: The base IEC publication dates from 1997 and is listed with an IEC stability date; national adoptions (BS EN and STB) reflect the same base text. Users should confirm with their national standards body for the latest status or any amendments.
Q: Is it part of a series?
A: Yes — it is Part 3-27 of the IEC/EN 61300 series (Basic test and measurement procedures) which contains multiple Part 3 documents covering examinations and measurements for fibre‑optic interconnecting devices and passive components.
Q: What are the key keywords?
A: Multiway connector, hole location, guide holes, fibre‑hole position, connector endface geometry, dimensional measurement, IEC 61300.